Part Number Hot Search : 
253801B PKG00 ACLPRE XP04114 FSB50450 D1033 XP04114 6KE120A
Product Description
Full Text Search
 

To Download DS1RGNA1BNP4BNP30 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ds1, cept-1, and cept2 3-76 exchangemax scs (select code 4346c) issue 3, jun 1999 bantam plus dsx-1/1c system patch cords and accessories bantam plus simplex and duplex standard and hybrid patch cords description the bantam plus C digital signal cross-connect-1/1c (dsx-1/ 1c) system patch cords consist of a family of standard and hybrid offerings. the term standard refers to cords having bantam-type plugs, either single or duplex, on both ends. the term hybrid refers to cords having a bantam-type plug on one end and a different plug, either 800-type or 310-type (long-frame) on the other end. there is also a new family of cords available called the ds-1 cross-connect regenerator cords. these cords boost the -20 db ds-1 monitor signal level by 20 db to produce a standard ds-1 signal level. this feature allows ds-1 circuits from dsx equipment, including bantam plus C dsx system, to be bridged to other dsx equipment while the circuit is in service. the cord configurations available are as follows: ? standard bantam-to-bantam ? hybrid bantam-to-800-type ? hybrid bantam-to-310 (long-frame) ? 800-type-to-bantam regenerator ? bantam-to-800-type regenerator ? bantam-to-bantam regenerator. patch cord specifications electrical and transmission ? meets ul requirements for telephone circuits operating at 100 ma or less and a maximum of 56.5 v dc with a ring voltage not exceed 150 v rms ? impedance: 100 ohms ? attenuation: 0.025 db/ft at ds-1 rate ? return loss: equal to or greater than 26 db for patch cords (12 feet [3.7 m]) long or less. mechanical ? bantam-type plugs: brass, 0.173 in. (4.4 mm) diameter ? conductor: 24 awg (0.51 mm) solid copper ? outer jacket: white flame-retardant pvc (bantam-to-bantam and bantam-to-310 configurations) ? minimum breaking or connector pull-off strength: 65 ibs. (289 n) for the standard bantam-to-bantam configurations environmental ? operating temperature: -40f/c to +185f (85c) ? humidity: 0 to 95 percent exmax.book : digital_2.fm page 76 wednesday, june 23, 1999 8:03 am
exchangemax scs (select code 4346c) 3-77 issue 3, jun 1999 ds1, cept-1, and cept2 standard bantam-to-bantam cords ordering information standard simplex bantam patch cord the bantam plus - dsx system uses either simplex or duplex standard cords. these cords are compatible with other manufacturers' panels using bantam-type jacks. cords use three- conductor plugs with single plug cords using two-conductor shielded cable and dual (duplex) plug cords using four-conductor shielded cable with plug sleeves common. cords are pvc jacketed and plugs are overmolded onto cables. cable and overmolding color is white on the bantam-to-bantam cords. the patch cords are capable of connecting both ds1 and ds1c signals. duplex cords are wired straight ; thus, to connect the out jack of one dsx to the in jack of another dsx requires rotating (flipping) the orientation of the duplex plugs at one end of the cord relative to the plug at the opposite end. for other lengths, contact your lucent technologies account representative. standard duplex bantam patch cords apparatus code description comcode simplex patch cords dsx1p1a-01-bnp 1-foot (0.3 m) simplex bantam patch cord 106 578 321 dsx1p1a-03-bnp 3-foot (0.9 m) simplex bantam patch cord 106 578 503 dsx1p1a-06-bnp 6-foot (1.8 m) simplex bantam patch cord 106 578 511 dsx1p1a-12-bnp 12-foot (3.7 m) simplex bantam patch cord 106 578 529 dsx1p1a-25-bnp 25-foot (7.6 m) simplex bantam patch cord 106 578 537 dsx1p1a-50-bnp 50-foot (15.2 m) simplex bantam patch cord 106 578 545 duplex patch cords dsx1p2a-01-bnp 1-foot (0.3 m) duplex bantam patch cord 106 578 552 dsx1p2a-03-bnp 3-foot (0.9 m) duplex bantam patch cord 106 578 560 dsx1p2a-06-bnp 6-foot (1.8 m) duplex bantam patch cord 106 578 578 dsx1p2a-10-bnp 10-foot (3.0) duplex bantam patch cord 108 174 236 dsx1p2a-12-bnp 12-foot (3.7 m) duplex bantam patch cord 106 578 586 dsx1p2a-15-bnp 15-foot (4.6 m) duplex bantam patch cord 108 174 269 dsx1p2a-20-bnp 20-foot (6.1 m) duplex bantam patch cord 108 174 269 dsx1p2a-25-bnp 25-foot (7.6 m) duplex bantam patch cord 106 578 594 dsx1p2a-50-bnp 50-foot (15.2 m) duplex bantam patch cord 106 578 644 length simplex bantam simplex bantam length duplex bantam duplex bantam exmax.book : digital_2.fm page 77 wednesday, june 23, 1999 8:03 am
ds1, cept-1, and cept2 3-78 exchangemax scs (select code 4346c) issue 3, jun 1999 bantam plugs accessory plugs for the bantam plus - dsx system include terminating, dummy, looping, and circuit guard plugs. for testing of digital equipment prior to cutover, a looping plug loops the out circuit to the in. a terminating plug is used to provide a resistive load on a digital circuit, typically during testing or maintenance patching. four resistor values are available. the 100-ohm terminating plug is intended to terminate ds1/1c circuits. the 135-ohm, 60-ohm, and 900-ohm terminating plugs are intended for voice-frequency circuits and are not usually needed with the dsx system. a dummy plug, when inserted, opens the normally closed contacts within the bantam jack and is useful during transition procedures where it is desirable to prerun cross-connects without causing long y-splices. circuit guard plugs are plastic, snap-in jack caps that block access to the out, in, or mon circuit jacks. they are used to prevent the inadvertent interruption of service that could be caused by inserting a plug into the out or in jack positions. circuit guard plugs are available in red, black, or white. ordering information code description comcode dsx1tp1-100bna 100-ohm terminating plug 106 578 651 dsx1tp1-135bna 135-ohm terminating plug 106 588 486 dsx1tp1-600bna 600-ohm terminating plug 106 588 510 dsx1tp1-900bna 900-ohm terminating plug 106 588 551 dsx1dp1-blkbna black dummy plugs (package of ten) 106 578 685 dsx1lp1-whtbna white looping plug 106 578 693 dsx1cg1-redbna red circuit guard plugs (package of ten) 106 578 701 dsx1cg1-blkbna black circuit guard plugs (package of ten) 106 588 569 dsx1cg1-whtbna white circuit guard plugs (package of ten) 106 588 577 exmax.book : digital_2.fm page 78 wednesday, june 23, 1999 8:03 am
exchangemax scs (select code 4346c) 3-79 issue 3, jun 1999 ds1, cept-1, and cept2 accessory plug coding hybrid patch cordsbantam-to-800-type 1-foot single bantam-type female to 800-type male patch cord (800f/1) bantam-type single male to 800-type single male patch cord (800h/length) ordering information patch cords are available to patch between a bantam-type jack and an 800-series or 900-series dsx jack or dixi-1 dsx jack. 800-type male duplex to bantam-type male duplex patch cord (800hd/length) ordering information ordering information for the 800-type-to bantam hybrid duplex patch cords is provided below. see 365-301-120 for information on the 800-series and 900-series dsx systems, or 365-301-121 for the dixi-1 system dsx1 p 1 a 03 bnp - type of plug * - bnp = bantam - lfp = 310 (long-frame) length (in feet) design iteration cord/cable type - 1 = simplex - 2 = duplex patch cord system type * - type of plug on one end of patch cord. opposite end has a bantam-type plug. - 1' - 0" (.3 m) bantam-type female 800-type male bantam-type male 800-type male length apparatus code description comcode 800/f1 1-foot (0.3 m) patch cord, bantam-type single female to 800-type single male 104 366 893 800h/12 12-foot (3.7 m) patch cord, bantam-type single male to 800-type single male 104 366 927 bantam-type male duplex white 800-type male duplex length apparatus code description comcode 800hd/3 3-foot (0.9 m) patch cord, 800-type male duplex to bantam-type male duplex 105 774 012 800hd/6 6-foot (1.8 m) patch cord, 800-type male duplex to bantam-type male duplex 105 774 020 exmax.book : digital_2.fm page 79 wednesday, june 23, 1999 8:03 am
ds1, cept-1, and cept2 3-80 exchangemax scs (select code 4346c) issue 3, jun 1999 hybrid patch cordsbantam-to-310 (long-frame) 12-foot bantam-type simplex to 310-type simplex patch cord bantam-type duplex to 310-type duplex patch cord ordering information patch cords are available to patch between bantam-type jacks and 310-type jacks (long frame). the 310-type jacks are often foun d on obsolete dsx-1/1c panels, such as ed-1c544-30 or ed-2c544-30 panels. miscellaneous accessory kits the miscellaneous cord and plug kit (dsx1mak1-1a-bna, comcode 106 727 860) includes commonly used bantam plus - dsx system patch cords, plugs, and circuit guards. the "soak kit" (dsx1mak1-1a-blp, comcode 107 995 110) consists of a total of 29 patch cords, used to assist in a soak test for a ds1-ds3 multiplexer. note: additional kits can be developed upon request. contact your local account representative or call 1-800-344-0223, ext. 3122, for additional information. ordering information 800hd/12 12-foot (3.7 m) patch cord, 800-type male duplex to bantam-type male duplex 105 774 038 800hd/25 25-foot (7.6 m) patch cord, 800-type male duplex to bantam-type male duplex 105 774 046 800hd/50 50-foot (15.2 m) patch cord, 800-type male duplex to bantam-type male duplex 105 774 053 apparatus code description comcode length simplex 310 simplex bantam length duplex 310 duplex bantam apparatus code description comcode dsx1p1a-25-lfp 10-foot (3.0 m) bantam-type simplex to 310-type simplex patch cord 106 678 519 dsx1p1a-12-lfp 12-foot (3.7 m) bantam-type simplex to 310-type simplex patch cord 106 700 875 dsx1p2a-03-lfp 3-foot (0.9 m) bantam-type duplex to 310-type duplex patch cord 106 700 891 dsx1p2a-05-lfp 5-foot (1.5 m) bantam-type duplex to 310-type duplex patch cord 108 174 319 dsx1p2a-06-lfp 6-foot (1.8 m) bantam-type duplex to 310-type duplex patch cord 106 700 909 dsx1p2a-10-lfp 10-foot (3.0 m) bantam-type duplex to 310-type duplex patch cord 108 174 335 dsx1p2a-12-lfp 12-foot (3.7 m) bantam-type duplex to 310-type patch cord 106 700 917 dsx1p2a-15-lfp 15-foot (4.6 m) bantam-type duplex to 310-type patch cord 106 991 433 dsx1p2a-20-lfp 20-foot (6.1 m) bantam-type duplex to 310-type patch cord 108 174 368 dsx1p2a-25-lfp 25-foot (7.6 m) bantam-type duplex to 310-type patch cord 106 991 441 dsx1p2a-30-lfp 30-foot (9.1 m) bantam-type duplex to 310-type patch cord 108 178 120 dsx1p2a-40-lfp 40-foot (12.2 m) bantam-type duplex to 310-type patch cord 108 174 400 dsx1p2a-50-lfp 50-foot (15.2 m) bantam-type duplex to 310-type patch cord 107 041 840 dsx1p2a-75-lfp 75-foot (22.9 m) bantam-type duplex to 310-type patch cord 108 174 418 apparatus code comcode description miscllaneous accessory kitdsx1mak1-1a-bnacomcode 106 727 860 dsx1tp1-100bna 106 578 651 100-ohm terminating plug C qty. four exmax.book : digital_2.fm page 80 wednesday, june 23, 1999 8:03 am
exchangemax scs (select code 4346c) 3-81 issue 3, jun 1999 ds1, cept-1, and cept2 ds1 regenerator cords the ds1 cross-connect regenerator cords are a family of hand-held regenerators for ds1-type signals. these cords boost the -20 db ds1 monitor signal level by 20 db to produce a standard ds1 signal level. this allows ds1 circuits to be bridged while the circuit is in-service. each regenerator cord assembly consists of a 4-foot (1.2 m) input cord and plug, a 3.8-inch long by 2.4-inch wide by 0.9-inch deep (97 mm by 51 mm by 23 mm) regenerator unit, and either a 30- foot (9 m) or 60-foot (18 m) output cord and plug. there are two configurations of regenerator cords available: ? 800-type-to-bantam C 800-type input to bantam-type output ? bantam-to-bantambantam-type input to bantam-type out- put. each regenerator unit has three light-emitting diodes (leds) located on the front of the box to assist with diagnostics. the green power led lights when power is applied. the green signal present led lights when a signal is present at the regenerator's input. the yellow bpv led lights when bipolar violations (bit errors) are detected in the bit stream. the input cord plugs into the monitor (mon) jack of a dsx circuit. when the output cord is plugged into the in jack of a second dsx circuit, the signal from the first dsx circuit is bridged to the second dsx circuit. power for the regenerator cords is provided by one of two methods, depending on the type of plug (800-type or bantam-type) used for the input. the cords with an 800-type input plug receive - 48 v from the mon jack of the 800a-type jack block. the cords with a bantam-type input plug receive their power via an additional cord equipped with a plug that slides onto any available power/ ground wire-wrap pins (for example, a connecting block that is wired to a fuse and alarm panel). the regenerator cords equipped with an 800-type output plug contain a 100-ohm resistor for terminating cross-connect circuits. cords equipped with a bantam-type output plug will not automatically terminate the cross-connect circuits. dsx1tp1-600bna 106 588 510 600-ohm terminating plug C qty. one dsx1tp1-900bna 106 588 551 900-ohm terminating plug C qty. one dsx1lp1-whtbna 106 578 693 white looping plug C qty. four dsx1dp1-blkbna 106 578 685 black dummy plug C qty. one pkg. of ten dsx1cg1-redbna 106 578 701 red circuit guard C qty. one pkg. of ten dsx1p1a-01-bnp 106 578 321 1-foot (0.3 m) simplex patch cord C qty. two dsx1p2a-01-bnp 106 578 552 1-foot (0.3 m) duplex patch cord C qty. two dsx1p1a-03-bnp 106 578 503 3-foot (0.9 m) simplex patch cord C qty. two dsx1p2a-03-bnp 106 578 560 3-foot (0.9 m) duplex patch cord C qty. two dsx1p1a-06 bnp 106 578 511 6-foot (1.8 m) simplex patch cord C qty. two dsx1p2a-06-bnp 106 578 578 6-foot (1.8 m) duplex patch cord C qty. two dsx1p1a-12-bnp 106 578 529 12-foot (3.7 m) simplex patch cord C qty. two dsx1p2a-12-bnp 106 578 586 12-foot (2.7 m) duplex patch cord C qty. two dsx1p1a-12-lfp 106 700 875 12-foot (3.7 m) bantam simplex to 310 simplex patch cord C qty. two dsx1p2a-12-lfp 106 700 917 12-foot (3.7 m) bantam duplex to 310 duplex patch cord C qty. two ds-1/1c "soak kit"dsx1mak1-1a-blpcomcode 107 995 110 dsx1p1a-01-bnp 106 578 321 1-foot (0.3 m) simplex patch cord C qty. 27 dsx2p1a-06-bnp 106 578 511 6-foot (1.8 m) simplex patch cord C qty. two apparatus code comcode description exmax.book : digital_2.fm page 81 wednesday, june 23, 1999 8:03 am
ds1, cept-1, and cept2 3-82 exchangemax scs (select code 4346c) issue 3, jun 1999 800-type-to-bantam regenerator cords ordering information bantam-to-bantam regenerator cords ordering information 800-type-to-bantam regenerator cord the 800-type-to-bantam regenerator cords are equipped with an 800-type plug at the input end and a bantam-type plug at the output end. the cords are used to bridge a ds1 circuit from an 800a-type jack block to a bantam panel. apparatus code description comcode ds1rgna1800/4/bnp/30 30-foot (9.1 m) cord, 800-type input, bantam-type output 106 982 432 ds1rgna1800/4/bnp/60 60-foot (18.2 m) cord, 800-type input, bantam-type output 107 050 353 bantam-to-bantam regenerator cord the bantam-to-bantam regenerator cord is equipped with a bantam-type plug and power plug at the input end and a bantam-type plug at the output end. the cord is used to bridge a ds1 circuit from one bantam panel to another bantam panel. apparatus code description comcode ds1rgna1bnp/4/bnp/30 30-foot (9.1 m), bantam-type input, bantam-type output regenerator cord 106 982 424 800-type male plug bantam-type male plug 4 feet (1.2 m) ds1rgna1800/4/bnp/30 - 30 feet (9.1 m) ds1rgna1800/4/bnp/60 - 60 feet (18.2 m) 800-type male plug bantam-type male plug power plug 4 feet (1.2 m) ds1rgna1bnp/4/800/30 - 30 feet (9.1 m) ds1rgna1bnp/4/800/60 - 60 feet (18.2 m) exmax.book : digital_2.fm page 82 wednesday, june 23, 1999 8:03 am
exchangemax scs (select code 4346c) 3-83 issue 3, jun 1999 ds1, cept-1, and cept2 jumper wire the recommended cross-connect wire for use with the bantam plus C dsx system is five-conductor y2-type wire. this wire consists of two pairs (one for each direction of transmission) and a fifth wire for cross-connecting the tracing lamp circuits. the wire has tinned, 24-gauge (0.51 mm), dual-insulated conductors, with irradiated pvc over semirigid pvc, for excellent toughness and transmission characteristics. it is available either on spools or coils. for cross-connections requiring a single pair, use two-conductor y1-type wire. for example, when cross-connecting a maintenance line to a quasi-random signal source (qrss) fanout circuit. ordering information cables two families of cable are recommended for connecting circuits to the dsx: the 1249c series and the 600c series. 1249c cable the 1249c is 26 awg (0.40 mm) twisted pair with dual solid pe/ pvc insulation, an inner jacket or buffer, a dual aluminum-foil shield with solid 24 awg (0.51 mm) drain wire, and a pvc jacket. the cable is recommended for all cable runs to the dsx up to 450 feet (137 m) and cross-aisle tie circuits between dsx lineups. space saving advantages are so significant, that with the 25 pair, eight cables will fit into about the same space as four of the 600c with foil shield or three of the earlier 600b with corrugated aluminum shield. the 1249c series cable is lighter weight and easier to handle than either of the 600 series. the transmission characteristics include attenuation of 6.5 db/1,000 feet (305 m) at 772 khz and characteristic impedance of 100 ohms (nominal), which makes it ideal for ds1. the cable comes in configurations of 4 to 50 pairs and, as of this printing, has a ul-type cmr listing on all pair sizes except for the four pair which has a ul-type cm listing. there is also a plenum version of the cable available with product code 2249c and a ul-type cmp listing. 1161a-type cable for cable runs to the dixi-1 greater than 450 feet (137 m) and up to 565 feet (172 m), the 1161a cable family is recommended. the 1161a cable family is constructed with a 24 awg (.51mm) twisted pair with a hdpe insulation and a single aluminum/ polymer foil laminate shield with solid 24 awg (.51 mm) drain wire and a pvc jacket. the 1161a cable has 20% reduction in cable diamater compaired to the 600c series cable of like pair counts and a 25% reduction in the cable diameter compaired to the 600b cable of like pair counts. it is also lighter in weight and easier to handle than either the 600 series cable families. its transmission characteristics include attenuation of 6.0 db/100 feet (305 m) at 772 khz and a characteristic impedance of 100 ohms (nominal). this product is ul listed type cmr and c(ul) cmg 75c for all pair sizes. 600c-type cable the 600c-type cable is 22 awg (0.64 mm) twisted pair with dual solid pe/pvc insulation. the 600c cable has a dual aluminum foil shield with solid 22 awg drain wire and a pvc jacket. it is significantly more flexible, lighter in weight, and is easier to handle than the earlier 600b-type with corrugated aluminum shield. because of the larger gauge, its transmission characteristics include attenuation of 4.1 db/1,000 feet (305 m) at 772 khz and characteristic impedance of 100 ohms (nominal). available in 6- to 32-pair configurations, the 600c cable has a ul-type cmr listing on pair sizes 25 to 32 and ul-type cm listing on pair sizes 6 to 16. it is recommended for cable runs up to 655 feet (200 m). the maximum length of a cable between the digital equipment and the dsx is 655 feet (200 m). this is consistent with the range of settings available on the equipment line build outs. for runs greater than 655 feet (200 m), intra-office repeaters (ior) are required. ordering information selected cable codes are provided in the following tables. all comcodes listed are for variable length packages (rvar). this allows the desired length to be ordered rather than requiring a minimum order quantity. see the electronic wire and cable catalog, select code 3807b, for further information. code description comcode y2-5c/24 s660 five-conductor, 660-foot spool, four per box 105 271 209 ccw-p 1/24 s/1000 one pair, 1,000-foot spool 102 590 791 exmax.book : digital_2.fm page 83 wednesday, june 23, 1999 8:03 am
ds1, cept-1, and cept2 3-84 exchangemax scs (select code 4346c) issue 3, jun 1999 1249c non-plenum series cable (26 awg) 2249c plenum series cable (26 awg) 1161a-series cable (24 awg) 600c-series cable (22awg) apparatus code description diameter comcode 1249 004c rvar 4 pair 0.27 inches (6.86 mm) 106 371 313 1249 006c rvar 6 pair 0.28 inches (7.11 mm) 106 371 339 1249 012c rvar 12 pair 0.35 inches (8.89 mm) 106 371 545 1249 016c rvar 16 pair 0.38 inches (9.65 mm) 106 371 560 1249 020c rvar 20 pair 0.42 inches (10.67 mm) 106 371 370 1249 025c rvar 25 pair 0.45 inches (11.43 mm) 106 371 396 1249 028c rvar 28 pair 0.45 inches (11.43 mm) 106 371 404 1249 032c rvar 32 pair 0.47 inches (11.94 mm) 106 371 446 1249 050c rvar 50 pair 0.61 inches (15.49 mm) 106 371 461 apparatus code description diameter comcode 2249 004c rvar 4 pair 0.21 inches (5.33 mm) 106 078 462 2249 012c rvar 12 pair 0.305 inches (7.75 mm) 106 078 280 2249 020c rvar 20 pair 0.375 inches (9.53 mm) 106 078 348 2249 025c rvar 25 pair 0.41 inches (10.41 mm) 106 078 363 2249 028c rvar 28 pair 0.43 inches (10.92 mm) 106 078 389 2249 032c rvar 32 pair 0.45 inches (11.43 mm) 106 078 405 2249 050c rvar 50 pair 0.50 inches (12.70 mm) 106 078 439 apparatus code description diameter comcode 1161 004a rvar 4 pair 0.26 inches (6.6 mm) 108 236 605 1161 006a rvar 6 pair 0.28 inches (7.1 mm) 108 236 613 1161 012a rvar 12 pair 0.35 inches (8.9 mm) 108 236 621 1161 016a rvar 16 pair 0.39 inches (9.9 mm) 108 236 647 1161 025a rvar 25 pair 0.48 inches (12.2 mm) 108 236 662 1161 028a rvar 28 pair 0.51 inches (13.0 mm) 108 324 609 1161 032a rvar 32 pair 0.55 inches (14.0 mm) 108 341 744 1161 050a rvar 50 pair 0.65 inches (16.5 mm) 108 236 696 apparatus code description diameter comcode 606c-6/22 rvar 6 pair 0.34 inches (8.64 mm) 106 556 491 607c-12/22 rvar 12 pair 0.43 inches (10.92 mm) 106 556 541 608c-16/22 rvar 16 pair 0.49 inches (12.45 mm) 106 556 514 609c-25/22 rvar 25 pair 0.59 inches (14.99 mm) 106 556 608 616c-28/22 rvar 28 pair 0.64 inches (16.26 mm) 106 556 624 613c-30/22 rvar 30 pair 0.64 inches (16.26 mm) 106 556 640 615c-32/22 rvar 32 pair 0.66 inches (16.76 mm) 106 556 723 618c-56/22 rvar 56 pair 0.86 inches (21.8 mm) 107 732 398 exmax.book : digital_2.fm page 84 wednesday, june 23, 1999 8:03 am


▲Up To Search▲   

 
Price & Availability of DS1RGNA1BNP4BNP30

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X